Material Savings through Rocking Isolation
Allowing a fully modular steel high-rise building to rock on its foundation, restrained by vertical post-tensioned tendons, greatly reduces the seismic forces that its structure and inter-module connections must resist. Compared with a conventional fixed-base building, rocking isolation lowers the base shear, overturning moment and connection demands, which leads to significant savings in structural steel and connection hardware. The work also finds the range of building heights where these benefits are greatest, so engineers can judge when rocking isolation is the most efficient design choice.